Podsumowanie treści

Strona 1

www. .com jungeraudiod07

Strona 2

A 2 –Installation The digital transmission processor d07 has a digital signal output. For the problem-free combination of following digital devices,

Strona 3 - FOREWORD

A 2 –Installation The digital audio toolbox b40 can be remote-controlled by means of parallel GPI contacts. use : remote-controlled changeover o

Strona 4 - CONTENT

A 2 –Installation The digital audio level processor d07 can transmit specific device statuses via parallel Tally lines. use: monitoring of the

Strona 5

A 2 –Installation The d07 can be remote-controlled by means of serial remote RS-232/422 or via the CAN-bus. use : remote-controlled changeover o

Strona 6

A 2 –Installation Connector : RJ 45 with status LEDs Pin assignment of the connector : Pin Signal name Functions 1 TX + Ethernet send 2

Strona 7 - FUNCTIONAL DESCRIPTION

LOCATION OF PARTS AND CONTROLS ESC CURSOR UP CURSOR DOWN ENTER A 3 PRESET switch : Load / sav

Strona 8

POWER INPUT IEC mains input connector 85-264V, 50/60 Hz with integrated fuse REMOTE serial remote interface RS-422 (232) connector: 9p

Strona 9 - INSTALLATION

Selection of the serial remote interface J2 – RS-232 / RS-422: Selection of the serial remote interface (see 3.8.3) J3 – A / B: fo

Strona 10

To set the reference level manually, follow these steps: 1. Set all dip switches to “OFF” except #6, ADJ. –set it to ON 2. Adjust the potentiomete

Strona 11

A 4.1. – Front Panel Operation Operation The d07 transmission processor is very easy to use. You can do all settings with the keys on

Strona 13 - (RS-422)

A 4.1 – Front Panel Operation When you switch on the d07 the main display will show you the current controller software and hardwar

Strona 14 - LAN INTERFACE

A 4.1 – Front Panel Operation SETUP CONFIG INPUT INPUT 1: analog Select the input mode according to your input signal (analog/digital AES/E

Strona 15

A 4.1 – Front Panel Operation LEVEL MAGIC ON LEVELLER OPERATING LEVEL -40…0dBFS Desired target level for the levelling process. Reference Leve

Strona 16 - Configuration

A 4.1 – Front Panel Operation Initialize preset P5 TV uni P6 radio uni P8 Radio speech P8 TV live P9 TV Movie P10 Radio classic SETUP

Strona 17

A 4.1 – Front Panel Operation Initialize preset P1 P2 P3 P4 SETUP CONFIG INPUT analog LEVEL MAGIC on on on o

Strona 18

A 4.2. – operation via web browser 4.2. Web interface of the d07 After setting the IP address of the d07 (See chapter B6 Network int

Strona 19 - Operation

A 4.2 – operation via web browser 4.2.2 SETTING > PRESETS The d07 has 4 Presets. These Presets are named PR 1 to PR 4 by default. The status wi

Strona 20 - Preset / Setup

A 4.2. – operation via web browser 4.2.3 SETTING > DEVICE On the DEVICE tab you can assign a 16 digit name to the module, pe

Strona 21 - 2.0.1. and higher

A 4.2 – operation via web browser 4.2.4 SETTING > SETUP Level Magic selects the main operating mode. The processing can be used as the well kn

Strona 22

A 4.2. – operation via web browser 4.2.5 SETTING > GPI/O GPIs are useful if you want to recall settings remotely e.g. by presets

Strona 23 - PRESETS

FOREWORD FOREWORD Thank you for buying and using the transmission processor d07. You have not only acquired the latest generation of dig

Strona 24

A 4.2 – operation via web browser 4.2.6 CONTROLLER > SYSTEM CONFIG DEVICE you can assign the d07 a unique Device Name as well as a Device Loc

Strona 25 - 4.2 Webinterface

A 4.2. – operation via web browser 4.2.7 CONTROLLER > BACKUP / RESTORE Here you can get a backup file of the d07. Simply pres

Strona 26 - 4.2.2 SETTING > PRESETS

A 4.2 – operation via web browser 4.2.8 CONTROLLER > SOFTWARE UPDATE In the top part of the above window you can update the firmware of the ne

Strona 27 - 4.2.3 SETTING > DEVICE

A 4.2. – operation via web browser You can also update the DSP controller and the DSP itself by pressing <MODULES FIRMWARE SINGLE

Strona 28 - 4.2.4 SETTING > SETUP

A 4.2 – operation via web browser 4.2.9 CONTROLLER > REBOOT CONTROLLER Network controller can be rebooted.

Strona 29 - 4.2.5 SETTING > GPI/O

A 5 -Boot display and trouble shootingBOOT DISPLAY AND TROUBLE SHOOTING display meaning / explanation JUENGER AUDIO D07 display of model

Strona 30

A 5 -Boot display and trouble shooting Should have remained the device no more operable and/or in the program execution stand, recommends itself an

Strona 31

A6 -Technical specificationsTECHNICAL SPECIFICATIONS sample rate 44.1/48 kHz audio data format 24 bit DIGITAL IN/OUT AES/EBU

Strona 32

A6-Technical specifications SYNC IN WCLK connector BNC, 75Ohm, coaxial level TTL-level input format Wordclock AES/EBU connector BNC

Strona 33

B – APPLICATION NOTES B – APPLICATION NOTES 1. The Junger Audio Dynamics Processor Principle 2. The Junger Audio Com

Strona 34

CONTENT CONTENT A – OPERATION MANUAL 1. Function description 1.1. Basic description 1.2. Block diagram 2. Installation 2.1. Unpack the unit 2

Strona 36 - THE UNIT

B1 – The Junger Audio Dynamics Processor Principle THE JUNGER AUDIO DYNAMICS PROCESSOR PRINCIPLES Changing the dynamic range of an audio signal is i

Strona 37 - SPECIFICATIONS

B1 – The Junger Audio Dynamics Processor Principle Look Ahead/Signal Delay The digital implementation of the Junger Multi-loop design also permits

Strona 38

B 2: The Jünger Audio Compresor & Expander Principle Figure 1: Compressor characteristics Figure 2 Expander characteristics THE JÜNG

Strona 40

B 3 – The Junger Audio Dynamics Pocessing Presets THE JUNGER AUDIO DYNAMICS PROCESSING PRESETS For some of the control parameter it is possible t

Strona 42 - Multi - Band Multi - Loop

LEVEL MAGIC 1. Release 2005 Junger Audio BerlinIntroduction & Reference guide TM

Strona 43 - EXPANDER PRINCIPLE

LEVEL MAGIC Introduction & Reference guide d06 d07 b46 C8007 C8046 Program suppliers and broadcasters alike have long been plagued by ‘sur

Strona 44

Introduction & Reference guide LEVEL MAGIC d06 d07 b46 C8007 C8046 Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin

Strona 45 - PROCESSING PRESETS

CONTENT B – APPLICATION NOTES 1. The Junger Audio Dynamics Processor Principle 2. The Junger Audio Compressor & Expander Principle

Strona 46

LEVEL MAGIC Introduction & Reference guide d06 d07 b46 C8007 C8046 The transient processor immediately reduces or raises the level of a new pr

Strona 47 - Reference

Introduction & Reference guide LEVEL MAGIC d06 d07 b46 C8007 C8046 Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin

Strona 48 - LEVEL MAGIC™

LEVEL MAGIC Introduction & Reference guide d06 d07 b46 C8007 C8046 Parameter Range Description LEVELLER Operating Level -40…0dBFS Des

Strona 49

Introduction & Reference guide LEVEL MAGIC d06 d07 b46 C8007 C8046 Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin

Strona 50

LEVEL MAGIC Introduction & Reference guide d06 d07 b46 C8007 C8046 Factory presets Radio Classical TV Movie TV Live Radio Speech R

Strona 51 - Processor

B 6 – Network Integration NETWORK INTEGRATION of Jünger Audio devices d07 d06 Level Magic LT C8000-modules via C8702 LAN Cont

Strona 52 - LIMITER

B 6 – Network Integration A) Connect the device over a 9 pin serial cable (connected 1 to 1) to your PC. Start your terminal program (e.g. Start ->

Strona 53

B 6 – Network Integration You will get to the Hyper terminal window: Press <ENTER> and you will get the following informa

Strona 54

B 6 – Network Integration Scroll in the list and choose Internet Protocol (TCP/IP). Make sure that the ‘check box’ for this item is checked, and the

Strona 55 - of Jünger Audio devices

B 6 – Network Integration Then change the settings in order to be able to communicate with the device. You must choose an IP-addr

Strona 57

B 6 – Network Integration By clicking on CONTROLLER > SYSTEM CONFIGURATION you will be able to change the device’s network configuration according

Strona 58

B 7 FM-Transmission d07 FM-TRANSMISSION – d07 There are two important parameters for FM-Transmission  The frequency deviation, determined by t

Strona 59

For alignment of the d07 it is important to consider the level diagram of the overall transmission chain (see below):

Strona 60

B 7 FM-Transmission d07 To enhance the signal to noise ratio for FM transmission, Pre-Emphasis on the transmission end and De-Emphases

Strona 61

Frequency modulation The sketch below shows the principal influence of the modulation index m= ∆fc / fm to the spectrum of an FM signal. On the left

Strona 62

B 7 FM-Transmission d07 Pre-Emphasis Increase of high frequencies to enhance the signal to noise ratio for FM transmission equals to a t

Strona 65 - Double sideband

www.jungeraudio.com d07

Strona 66

A 1 –Function description FUNCTIONAL DESCRIPTION The mature technology of the digital transmission processor d07 has now been supplemented

Strona 67

A 1 – Function description features  2-channel digital audio amplifier and limiter for broadcast transmission signals  new Level Magic™ techno

Strona 68

A 2 –Installation INSTALLATION The digital audio level processor d07 was carefully packed in the factory and the packaging was designed to p