DEVICE
Device Name you can assign the module a name (up to 16 digits) and assign it
by pressing <CHANGE NAME>.
Platform shows the hardware platform of the C8840
Parameter Version shows the parameter version of the module controller
FIRMWARE
Controller shows the firmware of the module controller
FPGA shows the actual firmware of the Module FPGA
Bootloader shows the bootloader version
Restart Module <RESTART> performs a warm start (soft reset)
Initialize and Restore <INITIALIZE> restores the factory default values for all
Factory Defaults parameters of the module including all presets. The input bus
assignment will be set to S01 … S04, The outputs are turned
OFF and the bus drivers will be disabled.
Backup Settings and <BACKUP> will put all active parameters and the content of all
Presets to File presets into an XML file. You may store such file on a PC.
Restore Settings you may select <browse> a matching XML file from a PC.
and parameters from File <RESTORE> will overwrite all active parameters and the content
of the presets by the content of the backup file.