D*AP8
29
3G SDI Mode
Level B Stream A 3G-SDI signal may have two HD sub streams (e.g. for 3-D TV),
Select AKN as 3G-B standard select between stream 1 or 2 for embedded
audio. See SMPTE 425M for details.
Test Pattern Generator The interface offers a test generator to either check downstream
connections during installation or for use in case of an input fail but you
may also use it to move 16 independent audio channels over a single
coax cable from point to point
Mode [OFF / AUTO (Input Loss) / Always ON]
Video Format [Last valid / one of the defined SD / HD 3G formats (see specs)]
[Color Bars / Black Frame]
Setup GUI – INTERFACES – SDI I/O interface – De-Embedder
Audio Sync Source The HD SDI standard allows
(Async HD) for asynchronous audio. This
critical if you have decided to
synchronize the device on such
signal. Here you find a solution.
You may either use the
embedded word clock
Embedded Word [Auto / De-Embedder CH1
Clock (DEM 1) / OFF
OFF = synchronized to the
SDI carrier
Auto = In case of a-sync audio it is synchronized automatically to the
SDI carrier
DEM1= from de-embedder channel 1